Product Description:
B1100 Series with superior performance and rich function, can meet the requirement of water supply in different occasions and improve the quality of water supply system to achieve the effect of energy saving and environmental protection.

Main Features:
Delivery Head: Max.54m
Flow:Max.12m³/h
Start/stop the pump automatically
Variable frequency drive to lower pump power consumption
Integrated matching design
Medium Temperature:+15-70%
Application:
Applicable to Villa, School, Hotel, Sauna Room, Garden Irrigation, etc.
Product Details:

Installation/Test-Operation of the Product
1 Environmental Conditions
This product is designed for indoor use. If you want to install the product on outdoor areas, prepare facilities that can provide the product with protection against rain, wind and low temperature.
2 Installation Requirements

As shown in Figure 1, Figure 2, after installing and cleaning the pools, make sure to extract air. If the inside of the pump is filled with air, the pump may overheat by friction during operation to damage the internal parts.
The diameter of inlet pipe must be the same or large than the diameter of the pump inlet.
The inlet water level shall be higher than 2m from the center of the pump, as shown in Figure 1 and Figure 2. The inlet water level as shown in Figure 3 and Figure 4 is wrong.

B1100 Series with superior performance and rich function, can meet the requirement of water supply in different occasions and improve the quality of water supply system to achieve the effect of energy saving and environmental protection.

Model | Input Voltage | Output Power (kW) | Current (A) | Head (m) | Flow (m3/h) | Threaded Bore (Inlet/Outlet) |
B1100-MLH20311-S20007 | 50/60Hz | 0.55 | 2.0 | 37 | 2 | G1/G1 |
B1100-MLH3041-S2001 | 0.75 | 3.2 | 42 | 3 | G1/G1 | |
B1100-MLH8201-S20025 | 1.85 | 7.9 | 36 | 8 | G1.5/G1.5 |
Main Features:
Delivery Head: Max.54m
Flow:Max.12m³/h
Start/stop the pump automatically
Variable frequency drive to lower pump power consumption
Integrated matching design
Medium Temperature:+15-70%
Application:
Applicable to Villa, School, Hotel, Sauna Room, Garden Irrigation, etc.
Product Details:

Installation/Test-Operation of the Product
1 Environmental Conditions
This product is designed for indoor use. If you want to install the product on outdoor areas, prepare facilities that can provide the product with protection against rain, wind and low temperature.
2 Installation Requirements

As shown in Figure 1, Figure 2, after installing and cleaning the pools, make sure to extract air. If the inside of the pump is filled with air, the pump may overheat by friction during operation to damage the internal parts.
The diameter of inlet pipe must be the same or large than the diameter of the pump inlet.
The inlet water level shall be higher than 2m from the center of the pump, as shown in Figure 1 and Figure 2. The inlet water level as shown in Figure 3 and Figure 4 is wrong.