Bedford Automatic Frequency Conversion Constant Voltage Control Electric Domestic Water Booster Pump

Product Description:B1100 Series with superior performance and rich function, can meet the requirement of water supply in different occasions and improve the quality of water supply system to achieve the effect of energy saving and environmental protection.ModelInput VoltageOutput Power (kW)Current(A)Head (m)Flow 

Featured Products

Product Description:
B1100 Series with superior performance and rich function, can meet the requirement of water supply in different occasions and improve the quality of water supply system to achieve the effect of energy saving and environmental protection.
Bedford Automatic Inverter Constant Pressure Control Electric Residential Water Booster Pump
Model
Input Voltage
Output Power 
(kW)
Current
(A)
Head 
(m)
Flow (m3/h)
Threaded Bore
(Inlet/Outlet)
B1100-MLH20311-S20007
 
Single Phase 220V
50/60Hz
0.55
2.0
37
2
G1/G1
B1100-MLH3041-S2001
0.75
3.2
42
3
G1/G1
B1100-MLH8201-S20025
1.85
7.9
36
8
G1.5/G1.5

Main Features:
Delivery Head: Max.54m
Flow:Max.12m³/h
Start/stop the pump automatically
Variable frequency drive to lower pump power consumption
Integrated matching design
Medium Temperature:+15-70%


Application:
Applicable to Villa, School, Hotel, Sauna Room, Garden Irrigation, etc. 

Product Details:
Bedford Automatic Inverter Constant Pressure Control Electric Residential Water Booster Pump

Installation/Test-Operation of the Product
1 Environmental Conditions 
This product is designed for indoor use. If you want to install the product on outdoor areas, prepare facilities that can provide the product with protection against rain, wind and low temperature.
2 Installation Requirements
Bedford Automatic Inverter Constant Pressure Control Electric Residential Water Booster Pump


       As shown in Figure 1, Figure 2, after installing and cleaning the pools, make sure to extract air. If the inside of the pump is filled with air, the pump may overheat by friction during operation to damage the internal parts.
      The diameter of inlet pipe must be the same or large than the diameter of the pump inlet.
      The inlet water level shall be higher than 2m from the center of the pump, as shown in Figure 1 and Figure 2. The inlet water level as shown in Figure 3 and Figure 4 is wrong.

Bedford Automatic Inverter Constant Pressure Control Electric Residential Water Booster Pump





 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours